Step  | Action  | Yes  | No  | 
|---|---|---|---|
1  | Did you review the Instrument Cluster Description and Operation and perform the necessary inspections?  | Go to Step 2  | |
2  | Verify that the oil gage indicator is inoperative. Does the oil gage indicator operate normally?  | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems  | Go to Step 3  | 
3  | 
 Does the oil pressure indicator light?  | Go to Step 4  | Go to Step 5  | 
4  | Replace the oil pressure switch. Did you complete the repair?  | Go to Step 8  | --  | 
5  | 
 Is a short to ground or open condition present?  | Go to Step 6  | Go to Step 7  | 
6  | Repair the open in the YEL/BLK wire between the instrument panel cluster assembly and the oil pressure switch. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair?  | Go to Step 8  | --  | 
7  | Repair or replace the instrument panel cluster printed circuit. Refer to Printed Instrument Cluster Circuit Replacement . Is the repair complete?  | Go to Step 8  | --  | 
8  | Operate the system in order to verify the repair. Did you correct the condition?  | System OK  | Go to Step 3  |