Step  | Action  | Yes  | No  | 
|---|---|---|---|
Schematic Reference: Horn Schematics DEFINITION: Horns always on  | |||
1  | Did you review the Horn system description and operation and perform the necessary inspections?  | Go to Step 2  | |
2  | Verify the fault is present. Does the system operate normally?  | Go to Testing for Electrical Intermittents in Wiring Systems  | Go to Step 3  | 
3  | Remove the horn relay. Did the horn stop sounding?  | Go to Step 4  | Go to Step 5  | 
4  | With the horn relay still removed, test the switch signal circuit for ground. Is ground present?  | Go to Step 6  | Go to Step 7  | 
5  | Repair the short to voltage in the horn supply voltage circuit. Refer to Wiring Repairs in Wiring Systems. Did you find and complete the repair?  | Go to Step 8  | --  | 
6  | Repair the short to ground in the horn relay switch signal circuit. Refer to Wiring Repairs in Wiring Systems. Did you find and complete the repair?  | Go to Step 8  | |
7  | Replace the horn relay.. Did you complete the replacement?  | Go to Step 8  | |
8  | Operate the system in order to verify the repair. Did you correct the condition?  | System OK  | Go to Step 3  |