Important: 
   •  Do not turn the camshafts or start the engine for approximately  30 minutes
after replacing the valve lifters and camshafts.    •  Allow approximately 30 minutes for the valves to settle
in place.  Operating the valves before this time may cause valve or piston damage.    •  The valves may make a tapping/ticking sound after replacement  if air
is trapped in the valve lifter. Run the engine at 2000 RPM until    the air
  is purged from the lifter.    •  If the tapping/ticking does not stop, locate the defective lifter  with
a stethoscope and replace. Or, remove the cylinder head cover with the      engine
stopped and push the lifter down by hand with a force less than   20 kg   
(44 lbs) when the camshaft is on the base circle.  If  clearance exists   
between the camshaft and the lifter, the lifter is  faulty  and should be    replaced. 
Important: Cylinder head and camshaft damage may result if the bearing caps are incorrectly installed.
Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.
Tighten
Tighten the camshaft bearing caps in 3 progressive steps in the sequence  shown
to 11 N·m (97 lb in).