Step  | Action  | Yes  | No  | 
|---|---|---|---|
Schematic Reference: Interior Lights Schematics  | |||
1  | Did you review the Interior Lights Circuit Description and Operation and perform the necessary inspections?  | Go to Step 2  | |
2  | Verify that the dome lamps are always on. Does the system operate normally  | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems  | Go to Step 3  | 
3  | 
 Refer to Circuit Testing in Wiring Systems. Is a short to ground present?  | Go to Step 4  | Go to Step 5  | 
4  | Repair the short to ground in the door jamb switch circuit. Refer to Wiring Repairs in Wiring Systems. Is the repair complete?  | Go to Step 8  | --  | 
5  | Test the ground circuit of the Dome lamp circuit for a short to ground. Refer to Wiring Repairs in Wiring Systems. Is a short to ground present?  | Go to Step 6  | Go to Step 7  | 
6  | Repair the short to ground in the dome lamp ground circuit. Refer to Wiring Repairs in Wiring Systems. Is the repair complete?  | Go to Step 8  | --  | 
7  | Replace the Remote Control Door Lock Receiver. Refer to Remote Control Door Lock Receiver Replacement in Keyless Entry. Did you complete the repair?  | Go to Step 8  | --  | 
8  | Operate the system in order to verify the repair. Did you correct the condition?  | System OK  | Go to Step 3  |