Step  | Action  | Yes  | No  | 
|---|---|---|---|
1  | 
 Does warm air flow out of the rear HVAC outlet ducts?  | Go to Step 5  | Go to Step 2  | 
2  | Using an external vacuum source, apply vacuum to the coolant by pass valve assembly. Does the valve open and close?  | Go to Step 5  | Go to Coolant Bypass Valve Replacement in Heating, Ventilation and Air Conditioning  | 
3  | With the coolant by-pass valve removed, inspect the valve for binding. Does the valve move freely?  | Go to Step 5  | Go to Step 4  | 
4  | Replace the coolant by pass valve. Refer to Coolant Bypass Valve Replacement . 
 Is the repair complete?  | Go to Step 5  | Go to Coolant Bypass Valve Replacement in Heating, Ventilation and Air Conditioning  | 
5  | Cycle the HVAC controls in order to verify proper operation. Did you find and correct the condition?  | System OK  | Go to Step 2  |