| • | The condition may be intermittent. Refer to Testing for Intermittent Conditions and Poor Connections . | 
| • | Inspect the air delivery system for the following conditions: | 
| - | An obstruction to the airflow | 
| - | Air leaks | 
| - | Misaligned air ducts | 
| - | Broken or binding linkages or doors | 
| • | If the scan tool indicates that the Door Actual parameter is 5-10 counts from the Commanded Door parameter, then perform the recalibration procedure for the HVAC door actuators. Refer to Actuator Recalibration . | 
Step  | Action  | Yes  | No  | 
|---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: Air recirculation is inoperative or is always ON.  | |||
1  | Did you perform the Diagnostic System Check - Vehicle?  | Go to Step 2  | |
2  | 
 Does the scan tool indicate that the Recirculate Switch Parameter changes state?  | Go to Diagnostic Aids  | Go to Step 3  | 
3  | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition?  | Go to Step 5  | Go to Step 4  | 
4  | Replace the HVAC control module. Refer to Control Module References for replacement, setup, and programming. Did you complete the replacement?  | Go to Step 5  | --  | 
5  | Operate the system in order to verify the repair. Did you correct the condition?  | System OK  | Go to Step 2  |