Removal Procedure
- Remove the radiator support diagonal brace if applicable. Refer to 
Radiator Support Diagonal Brace Replacement
.
 
- Disconnect the secondary air injection (AIR) reaction pump inlet hose from the air cleaner air outlet duct.
 
- Loosen the 3 air cleaner housing retaining screws (1).
 
- Remove the air cleaner housing (2).
 
- Lift the air cleaner element (6) and air outlet duct (3) from the lower air cleaner housing/washer solvent tank assembly (4).
 
- Remove the air cleaner element (6) from the air outlet duct (3) with a twisting and pulling motion.
 
- Inspect the entire assembly for dust, debris, or water. Clean or replace as necessary.
 
Installation Procedure
- Install the air cleaner element (6) onto the air outlet duct (3) with a twisting and pushing motion.
 
- Install the air cleaner element (6) and air outlet duct (3) into the lower air cleaner housing/washer solvent tank assembly (4).
 
Notice: Refer to Fastener Notice in the Preface section.
Important: Ensure the air inlet duct (5) is properly positioned in the lower air cleaner housing/washer solvent tank assembly (4) before installing the air cleaner housing (2).
- Install the air cleaner housing (2).
 
Tighten
Tighten the 3 air cleaner housing retaining screws (1) to 4 N·m (35 lb in).
- Connect the AIR pump inlet hose to the air cleaner air outlet duct.
 
- Install the radiator support diagonal brace if applicable. Refer to 