Scan Tool Parameter  | Data List  | Units Displayed  | Typical Data Value  | 
|---|---|---|---|
Operating Conditions: Ignition ON/Engine OFF  | |||
Battery Voltage Signal  | Body, Generator Battery Control Module  | Volts  | 12.3 V  | 
Generator L Terminal Signal Command  | Body, Generator Battery Control Module  | Percent  | 0 Percent  | 
Regulated Voltage Control Current Sensor  | Body, Generator Battery Control Module  | Amps  | 1 Amp  | 
Running State of Charge  | Body, Generator Battery Control Module  | Percent  | 90 Percent  | 
Scan Tool Parameter  | Data List  | Units Displayed  | Typical Data Value  | 
|---|---|---|---|
Operating Conditions: Ignition ON/Engine OFF  | |||
Crank Request Signal  | Electrical/Theft Data  | Yes/No  | No  | 
Generator L Terminal Signal Command  | Electrical/Theft Data  | Off/On  | Off  | 
Generator F Terminal Signal  | Electrical/Theft Data  | %  | 10-90%  | 
Ignition 1 Signal  | Electrical/Theft Data  | volts  | 9.6-14.4v  | 
PNP Switch  | Electrical/Theft Data  | Park/Neutral, In Gear  | Park/Neutral  | 
Starter Relay Command  | Electrical/Theft Data  | Off/On  | Off  | 
Starter Relay Circuit Status  | Electrical/Theft Data  | Incomplete, Short Gnd/Open, Short to B+, OK  | OK  | 
Scan Tool Parameter  | Data List  | Units Displayed  | Typical Data Value  | 
|---|---|---|---|
Operating Conditions: Ignition ON/Engine OFF  | |||
Crank Request Signal  | Engine Data 3  | Yes/No  | No  | 
Generator L Terminal Signal Command  | Engine Data 2  | Off/On  | Off  | 
Generator F Terminal Signal  | Engine Data 2  | %  | 10-90%  | 
Ignition 1 Signal  | Engine Data 1, Engine Data 2, Engine Data 3  | volts  | 9.6-14.4v  | 
Starter Relay Command  | Engine Data 3  | Off/On  | Off  | 
Scan Tool Parameter  | Data List  | Units Displayed  | Typical Data Value  | 
|---|---|---|---|
Operating Conditions: Ignition ON/Engine OFF  | |||
TR Sw.  | Transmission Data  | Park, Reverse, Neutral, Drive 5, Drive 4, Drive 3, Drive 2, Drive 1  | Park  |