Step  | Action  | Yes  | No  | 
|---|---|---|---|
Schematic Reference: Exterior Lights Schematics Connector End View Reference: Lighting Systems Connector End Views  | |||
1  | Did you review the Exterior Lighting Systems Description and Operation and perform the necessary inspections?  | Go to Step 2  | |
2  | Verify that the hazard lamps are always on. Do the hazard lamps operate normally?  | Go to Testing for Intermittent Conditions and Poor Connections  | Go to Step 3  | 
3  | 
 Is a ground signal present?  | Go to Step 4  | Go to Step 5  | 
4  | Test the multifunction turn signal switch hazard switch signal circuit for a short to ground. Refer to Circuit Testing and Wiring Repairs . Did you find and correct a condition?  | Go to Step 9  | Go to Step 6  | 
5  | Inspect for poor connections at the harness connector of the hazard/turn flasher. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition?  | Go to Step 9  | Go to Step 7  | 
6  | Inspect for poor connections at the harness connector of the multifunction turn signal switch. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition?  | Go to Step 9  | Go to Step 8  | 
7  | Replace the hazard/turn flasher. Refer to Hazard and Turn Signal Flasher Replacement . Did you complete the repair?  | Go to Step 9  | --  | 
8  | Replace the multifunction turn signal switch. Refer to Turn Signal Multifunction Switch Replacement . Did you complete the repair?  | Go to Step 9  | --  | 
9  | Operate the system in order to verify the repair. Did you correct the condition?  | System OK  | Go to Step 3  |