| • | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. | 
| • | Review Strategy Based Diagnosis for an overview of the diagnostic approach. | 
| • | Diagnostic Procedure Instructions provides an overview of each diagnostic category. | 
Circuit  | Short to Ground  | Open/High Resistance  | Short to Voltage  | Signal Performance  | 
|---|---|---|---|---|
Generator Turn On Signal  | B1487  | --  | B1488  | --  | 
The generator battery control module (GBCM) controls the generator through the generator turn on signal circuit, or L-terminal circuit. The signal is a 5-volt pulse width modulation (PWM) signal of 128 Hz, and the GBCM varies the duty cycle. Normal duty cycle is between 5-95 percent when the engine is running. If the generator turn on signal circuit is in the 0-5 percent range, or pulled low to ground, then DTC B1487 will set.
The engine is running.
The generator turn on signal circuit has less than 5 percent duty cycle for 2 minutes.
| • | The charge indicator turns ON. | 
| • | The driver information center (DIC) displays the BATTERY NOT CHARGING message. | 
| • | The DTC will pass when the generator turn on signal circuit has 5-95 percent duty cycle. | 
| • | The charge indicator and DIC message will remain ON until the ignition is cycled after the DTC clears. | 
Starting and Charging Schematics
Charging System Description and Operation
Control Module References for scan tool information
| ⇒ | If less than the specified range, test the signal circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the GBCM. | 
| ⇒ | If greater than the specified range, test the signal circuit for a short to voltage. If the circuit tests normal, replace the GBCM. | 
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
| • | Control Module References for GBCM replacement, setup, and programming. |