| Table 1: | HVAC Control Module Scan Tool Data List | 
| Table 2: | Rear HVAC Control Module Scan Tool Data List | 
| Table 3: | PCM Scan Tool Data List | 
Scan Tool Parameter  | Data List  | Units Displayed  | Typical Data Value  | 
|---|---|---|---|
Operating Conditions: Engine idling, A/C ON, ambient air temperature between 22-27°C (70-80°F)  | |||
A/C Head Pressure  | A/C Permission  | Yes, No  | No  | 
A/C Switch  | Input/Output  | On, Off  | Off  | 
AC Compressor Feedback  | Input/Output  | On, Off  | Varies  | 
AC Permission  | Input/Output  | Withheld, Granted  | Varies  | 
AC/Heater Door Actual  | Door Positions  | Counts  | Varies  | 
AC/Heater Door Commanded  | Door Positions  | Counts  | Varies  | 
AC/Heater Motor Drive  | Door Positions  | Stop, Increase, Decrease  | Stop  | 
Air Mix Door Left Commanded  | Door Positions  | Counts  | Varies  | 
Air Mix Door Right Commanded  | Door Positions  | Counts  | Varies  | 
Battery Voltage  | Input/Output  | Volts  | 13.5-14.5 V  | 
Blower Motor Status  | Input/Output  | Active/Inactive  | Active  | 
Blower Speed  | A/C Permission  | Yes, No  | No  | 
Defrost Door Actual  | Door Positions  | Counts  | Varies  | 
Defrost Door Commanded  | Door Positions  | Counts  | Varies  | 
Defrost Motor Drive  | Door Positions  | Stop, Increase, Decrease  | Stop  | 
Engine Coolant Temp  | A/C Permission  | Yes, No  | No  | 
Engine Running  | A/C Permission  | Yes, No  | No  | 
Ign. Since Current DTC  | Input/Output  | Numeric  | 0  | 
Left Mix Door Actual  | Door Positions  | Counts  | Varies  | 
Left Mix Motor Drive  | Door Positions  | Stop, Increase, Decrease  | Stop  | 
Left Temp. Detent Pos.  | Input/Output  | 0-18  | Hot 18/Cold 0  | 
Mode Select Position  | Door Positions  | Off, Defrost, Heater, Htr/Def, Bi-level, Panel  | Varies  | 
Outside Air Temp  | A/C Permission  | Yes, No  | No  | 
Pressure Cycle Switch  | A/C Permission  | Yes, No  | No  | 
Pressure Cycle Switch  | Input/Output  | Low Pressure, Normal  | Varies  | 
Recirculate Switch  | Input/Output  | On, Off  | Off  | 
Right Mix Door Actual  | Door Positions  | Counts  | Varies  | 
Right Mix Motor Drive  | Door Positions  | Stop, Increase, Decrease  | Stop  | 
Right Temp. Detent Pos.  | Input/Output  | 0-18  | Hot 18/Cold 0  | 
Scan Tool Parameter  | Data List  | Units Displayed  | Typical Data Value  | 
|---|---|---|---|
Operating Conditions: Engine idling, A/C ON, ambient air temperature between 22-27°C (70-80°F)  | |||
Air Mix Door Actual  | Door Positions  | Counts  | Varies  | 
Air Mix Door Commanded  | Door Positions  | Counts  | Varies  | 
Battery Voltage  | Input/Output  | Volts  | 13.5-14.5 V  | 
Console Mode Door Actual  | Door Positions  | Counts  | 0.0 Volts  | 
Console Mode Door Commanded  | Door Positions  | Counts  | Varies  | 
Driver Override Switch  | Input/Output  | Rear, Off, Low, Med, High  | Varies  | 
Heater Water Valve  | Input/Output  | Open, Closed  | Closed  | 
Ign. Since Current DTC  | Input/Output  | Cycles  | Varies  | 
Mode Door Actual  | Door Positions  | Counts  | Varies  | 
Mode Door Commanded  | Door Positions  | Counts  | Varies  | 
Rear Blower Speed  | Input/Output  | Off, Low, Med, High  | Varies  | 
Rear HVAC Fan Speed  | Input/Output  | Off, Low, Med, High  | Varies  | 
Rear HVAC Motor Pos.  | Door Positions  | Lower, Bi-level, Upper  | Bi-level  | 
Rear Temp. Select Sw.  | Input/Output  | Counts  | Varies  | 
Rec. Mode from Front Control  | Door Positions  | Heater, Panel, Defrost, Bi-level, Htr./Def.  | Varies  | 
Scan Tool Parameter  | Data List  | Units Displayed  | Typical Data Value  | 
|---|---|---|---|
Operating Conditions: Engine idling, A/C ON, ambient air temperature between 22-27°C (70-80°F)  | |||
A/C High Side Pressure  | Engine Data 2  | kPa, psi  | 629-845 kPa (85-120 psi)  | 
A/C High Side Pressure  | Engine Data 2  | Volts  | Varies  | 
A/C Relay Command  | Engine Data 2  | On, Off  | Varies  | 
A/C Request Signal  | Engine Data 2  | Yes, No  | Varies  | 
ECT Sensor  | Engine Data 2  | °C/°F  | 92°C (197°F)  |