Step  | Action  | Yes  | No  | 
|---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: The temperature cannot be adjusted, or the cooling is insufficient during A/C operation.  | |||
1  | Did you perform the Diagnostic System Check - Vehicle?  | Go to Step 2  | |
2  | 
 Important: If during this diagnostic procedure the HVAC control module is disconnected a recalibration of actuators must be performed to avoid misdiagnosis. 
 Does the scan tool display any DTC B0414, B0424, B3761 or B3770?  | Go to Step 3  | |
3  | 
 Does the blower motor operate in any of the speed positions?  | Go to Step 4  | Go to Blower Motor Inoperative  | 
4  | Does the blower motor operate at the desired speed?  | Go to Step 5  | Go to Blower Motor Malfunction  | 
5  | 
 Does the recirculation door move from the recirculation position to the outside air position?  | Go to Step 6  | |
6  | Does the customer concern occur when the A/C is OFF?  | Go to Step 9  | Go to Step 7  | 
7  | 
 Important: Ambient air temperature must be above 3°C (36°F). 
 Does the A/C compressor operate?  | Go to Step 8  | |
8  | Perform the refrigerant system performance test. Refer to Air Conditioning (A/C) System Performance Test . Did you find and correct the condition?  | Go to Step 12  | Go to Step 9  | 
9  | 
 Does the Left Mix Door Actual and the Right Mix Door Actual parameters counts change?  | System OK  | Go to Step 10  | 
10  | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition?  | Go to Step 12  | Go to Step 11  | 
11  | Replace the HVAC control module. Refer to Control Module References for replacement, setup, and programming. Did you complete the replacement?  | Go to Step 12  | --  | 
12  | Operate the system in order to verify the repair. Did you correct the condition?  | System OK  | Go to Step 2  |