Tools Required
J 7872 
 Magnetic Base Dial Indicator Set, or equivalent
Important: This measurement procedure is intended to measure transmission or transfer case output flange runout for systems with a constant velocity (CV) joint, rubber coupling or bolt-on U-joint yoke at the transmission or transfer
case. 
- Place the transmission in NEUTRAL.
 
- Raise and support the vehicle. Refer to 
Lifting and Jacking the Vehicle
 .
 
- If equipped with a CV joint, measure the transmission or transfer case output flange radial runout on the machined surface of the prop shaft front CV joint housing, as close to the flange as possible:
 
| 3.1.  | Clean the surface of the prop shaft front CV joint housing just rear of the transmission or transfer case output flange. | 
 
| 3.2.  | Mount a dial indicator set, 
J 7872 
 , or equivalent, and position the dial indicator to contact the prop shaft front CV joint housing as close to the transfer case output flange as possible. | 
 
- If equipped with a rubber coupling or bolt-on U-joint yoke, measure the transfer case output flange radial runout on the machined surface of the flange pilot area:
 
| 4.1.  | Mark the position of the prop shaft to the transmission or transfer case output flange. | 
 
| 4.2.  | Separate the propshaft from the transmission or transfer case output flange. | 
 
| 4.3.  | Clean the surface of the flange pilot area. | 
 
| 4.4.  | Mount a dial indicator set, 
J 7872 
 , or equivalent, and position the dial indicator to contact the pilot area as close to the end of the pilot as possible. | 
 
- Rotate the transmission or transfer case output flange by hand to locate the low spot.
 
- Set the dial indicator to zero on the low spot.
 
- Rotate the flange or shaft by hand and record the amount of radial runout.
 
- Compare the runout of the flange or shaft to the runout tolerance specifications guideline.
 
- If the transmission or transfer case output flange runout exceeds the specification, the flange or shaft requires replacement.