Step 
 | Action 
 | Normal Result(s) 
 | Abnormal Result(s)* 
 | 
1 
 | 
- Turn the ignition switch off.
 
- Turn the ignition switch on.
 
 
 | 
|     •  | Defogger ON indicator is off. |  
  
 | 
Defoggers and Heated Mirrors Always On  
 | 
2 
 | 
- Press and release the defogger switch one time.
 
- Wait approximately 10 minutes.
 
 
 | 
|     •  | Defogger ON indicator comes on. |  
  
|     •  | After approximately 10 minutes, both the defogger ON indicator
and the defoggers turn off. |  
  
 | 
 | 
3 
 | 
- Press and release the Defogger switch one time.
 
- Wait approximately 5 minutes.
 
 
 | 
|     •  | Defogger ON indicator comes on. |  
  
|     •  | After approximately 5 minutes, both the defogger ON indicator
and the defoggers turn off. |  
  
 | 
 | 
4 
 | 
- Press and release the defogger switch one time.
 
- Wait approximately 15 seconds.
 
- Press and release the defogger switch a second time, before time-out
occurs.
 
 
 | 
|     •  | Defogger ON indicator comes on and the defoggers come on. |  
  
|     •  | When switch is pressed the second time, both the defogger ON indicator
and the defoggers turn off immediately. |  
  
 | 
 | 
* Refer to the appropriate
symptom diagnostic table for the applicable abnormal result. 
 |