Step  | Action  | Value(s)  | Yes  | No  | 
|---|---|---|---|---|
1  | Did you review the operation and perform the necessary inspections?  | --  | Go to Step 2  | Go to Symptoms  | 
2  | Disconnect the liftgate door lock (ajar indicator switch). Does the REAR HATCH AJAR message turn off on the IP reconfigurable telltale?  | --  | Go to Step 3  | Go to Step 4  | 
3  | Replace the liftgate door lock (ajar indicator switch). Refer to Liftgate Latch Replacement . Is the repair complete?  | --  | Go to Step 6  | --  | 
4  | Test the signal circuit of the trunk ajar switch for a short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition?  | --  | Go to Step 6  | Go to Step 5  | 
5  | Replace the IPC. Refer to Instrument Cluster Replacement in Instrument Panel, Gauges, and Console. Important: Perform the set up procedure for the IP. Did you complete the replacement and the set up procedure?  | --  | Go to Step 6  | --  | 
6  | Operate the system in order to verify the repair. Did you correct the condition?  | --  | System OK  | Go to Step 2  |