Important: The positive crankcase ventilation (PCV) valve is not removable from the valve rocker arm cover. The PCV valve and rocker arm cover must be replaced as an assembly.
Important: If the PCV valve is not defective it may be possible to clean the valve rather than replacing the rocker arm cover.
| 2.1. | Remove the screws (1) from the PCV baffle. | 
| 2.2. | Clean the PCV valve (3). | 
Notice: Refer to Fastener Notice in the Preface section.
| 1.1. | Install the PCV baffle (2). | 
| 1.2. | Install the PCV baffle screws (1). | 
Tighten
Tighten the screws to 6 N·m (53 lb in).