| Table 1: | HVAC Control Module Scan Tool Data List | 
| Table 2: | PCM Scan Tool Data List 3.5L (LX9) / ECM 3.9L (LZ9) | 
Scan Tool Parameter  | Data List  | Units Displayed  | Typical Data Value  | 
|---|---|---|---|
Operating Conditions: Engine Idling, A/C ON, Ambient Air Temperature Between 22-27°C (70-80°F)  | |||
A/C Request  | HVAC  | Yes/No  | Varies  | 
Recirculation Dr. Position  | HVAC  | Counts  | Varies  | 
Recirculation Dr. Motor Command  | HVAC  | Counts  | Varies  | 
Mode Dr. Position  | HVAC  | Counts  | Varies  | 
Mode Dr. Motor Command  | HVAC  | Counts  | Varies  | 
Defrost Dr. Position  | HVAC  | Counts  | Varies  | 
Defrost Dr. Motor Command  | HVAC  | Counts  | Varies  | 
Driver Temp. Dr. Position  | HVAC  | Counts  | Varies  | 
Driver Temp. Dr. Motor Command  | HVAC  | Counts  | Varies  | 
Psgr. Temp. Dr. Position  | HVAC  | Counts  | Varies  | 
Psgr. Temp. Dr. Motor Command  | HVAC  | Counts  | Varies  | 
Aux. Mode Dr. Position  | HVAC  | Counts  | Varies  | 
Aux. Mode Dr. Motor Command  | HVAC  | Counts  | Varies  | 
Aux. Temp. Dr. Position  | HVAC  | Counts  | Varies  | 
Aux. Temp. Dr. Motor Command  | HVAC  | Counts  | Varies  | 
Evaporator Temp. Sensor  | HVAC  | °C/°F  | Varies  | 
Evaporator Temp. Sensor  | HVAC  | Counts  | Varies  | 
Mode Status  | HVAC  | Recirc/Vent/ Mix-Blend/ Floor/ Bi-Level/ Defrost  | Varies  | 
A/C LED  | HVAC  | On/Off  | Varies  | 
Rear Defrost LED  | HVAC  | On/Off  | Varies  | 
Driver Heated Seat Status  | HVAC  | Off/Low Heat/High Heat  | Varies  | 
Passenger Heated Seat Status  | HVAC  | Off/Low Heat/High Heat  | Varies  | 
Blower Motor Switch Position  | HVAC  | Off/On but not High Blower/On and High Blower  | Varies  | 
Aux. Blower Motor Speed Command  | HVAC  | Counts  | Varies  | 
Aux. Blower Motor Switch Position  | HVAC  | Aux/Off/1/2/3/4  | Varies  | 
Aux. Blower Motor Speed  | HVAC  | Counts  | Varies  | 
Scan Tool Parameter  | Data List  | Units Displayed  | Typical Data Value  | 
|---|---|---|---|
Operating Conditions: Engine Idling, A/C ON, Ambient Air Temperature Between 22-27°C (70-80°F)  | |||
A/C Disengage Reason  | HVAC  | None/WOT/System Voltage/CKP Learn Active/Engine Run Time/Coolant Hot/Stall Prevention/ A/C Pressure/Engine Speed/Trans Engine Speed/ A/C Pressure Sensor/Low Voltage/High Voltage/Outside Air Temp/Switched OFF  | Varies  | 
A/C Off for WOT  | HVAC  | Yes/No  | Varies  | 
A/C Pressure Disable  | HVAC  | Yes/No  | Varies  | 
A/C High Side Pressure  | HVAC  | kPa/Psi  | Varies  | 
A/C High Side Pressure  | HVAC  | Volts  | Varies  | 
A/C Relay Command  | HVAC  | On/Off  | Varies  | 
A/C Relay Circuit History  | HVAC  | OK/Open/Short/Invalid State  | Varies  | 
A/C Request Signal  | HVAC  | Yes/No  | Varies  |