Step  | Action  | Yes  | No  | 
|---|---|---|---|
Schematic Reference: Starting and Charging Schematics  | |||
1  | Did you perform the Diagnostic System Check - Vehicle?  | Go to Step 2  | |
2  | Turn the ignition to the START position. Did the starter solenoid click?  | Go to Step 3  | |
3  | Inspect the engine and belt drive system for mechanical binding, seized engine, or seized generator. Does the engine move freely?  | Go to Step 4  | Go to Engine Will Not Crank - Crankshaft Will Not Rotate for the 3.5L (LX9) engine or Go to Engine Will Not Crank - Crankshaft Will Not Rotate for the 3.9L (LZ9) engine  | 
4  | Test the battery positive cable between the battery and the starter solenoid for high resistance. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition?  | Go to Step 8  | Go to Step 5  | 
5  | Test the ground circuit between the battery and the starter motor for a high resistance. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition?  | Go to Step 8  | Go to Step 6  | 
6  | Inspect for poor connections at the starter. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition?  | Go to Step 8  | Go to Step 7  | 
7  | Replace the starter. Refer to Starter Motor Replacement . Did you complete the replacement?  | Go to Step 8  | --  | 