Step  | Action  | Yes  | No  | 
|---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: The blower motor is inoperative in all speed positions.  | |||
1  | Did you perform the Diagnostic System Check - Vehicle?  | Go to Step 2  | |
2  | 
 Does the blower motor operate in each speed position?  | Go to Testing for Intermittent Conditions and Poor Connections  | Go to Step 3  | 
3  | 
 Does the test lamp illuminate?  | Go to Step 4  | Go to Step 6  | 
4  | Connect a test lamp between the blower motor supply voltage circuit and the ground circuit. Does the test lamp illuminate?  | Go to Step 8  | Go to Step 5  | 
5  | Test the ground circuit of the blower motor resistor assembly for an open or high resistance. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition?  | Go to Step 15  | Go to Step 9  | 
6  | 
 Does the test lamp illuminate?  | Go to Step 9  | Go to Step 7  | 
7  | 
 Does the test lamp illuminate?  | Go to Step 10  | Go to Step 11  | 
8  | Inspect for poor connections at the harness connector of the blower motor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition?  | Go to Step 15  | Go to Step 12  | 
9  | Inspect for poor connections at the harness connector of the blower motor resistor assembly. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition?  | Go to Step 15  | Go to Step 13  | 
10  | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition?  | Go to Step 15  | Go to Step 14  | 
11  | Repair the ignition 3 voltage circuit of the HVAC control module. Refer to Wiring Repairs . Did you complete the repair?  | Go to Step 15  | --  | 
12  | Replace the blower motor. Refer to Blower Motor Replacement . Did you complete the replacement?  | Go to Step 15  | --  | 
13  | Replace the blower motor resistor assembly. Refer to Blower Motor Resistor Assembly Replacement . Did you complete the replacement?  | Go to Step 15  | --  | 
14  | Replace the HVAC control module. Refer to Control Module References for replacement, setup, and programming. Did you complete the replacement?  | Go to Step 15  | --  | 
15  | Operate the system in order to verify the repair. Did you correct the condition?  | System OK  | Go to Step 3  |