| Table 1: | HVAC Control Module Scan Tool Data Parameters | 
| Table 2: | HVAC Control Module Scan Tool Output Controls | 
Parameter  | System State  | Expected Value  | Description  | 
|---|---|---|---|
Operating Conditions: Ignition ON  | |||
A/C Evap. Temperature Sensor  | --  | Varies  | This displays Counts. This is the evaporator temperature measured in counts.  | 
A/C LED  | --  | Off  | The scan tool displays On or Off. This is the state of the air conditioner light emitting diode (LED) indicator.  | 
A/C Request  | --  | No  | The scan tool displays Yes or No. Yes is displayed if the air conditioner is requested.  | 
Aux. Blower Motor Speed  | --  | Varies  | This displays Counts. This is the auxiliary blower motor speed measured in counts.  | 
Aux. Blower Motor Switch  | --  | Off  | The scan tool displays Invalid, Auxiliary, Off, 1, 2 or 3. This is the state of the auxiliary blower motor switch.  | 
Aux. Blower Mtr. Spd. Command  | --  | Varies  | This displays Counts. This is the commanded auxiliary blower motor speed measured in counts.  | 
Aux. Mode Door Actual  | --  | Varies  | This displays Counts. This is the actual auxiliary mode door position measured in counts.  | 
Aux. Mode Door Commanded  | --  | Varies  | This displays Counts. This is the commanded auxiliary mode door position measured in counts.  | 
Aux. Temp. Dr. Motor Command  | --  | Varies  | This displays Counts. This is the commanded auxiliary temperature door motor measured in counts.  | 
Aux. Temp. Dr. Position  | --  | Varies  | This displays Counts. This is the auxiliary temperature door position measured in counts.  | 
Blower Motor Switch  | --  | Off  | The scan tool displays Off, On, High or Invalid. This is the state of the blower motor switch.  | 
Defrost Door Actual  | --  | Varies  | This displays Counts. This is the actual defrost door position measured in counts.  | 
Defrost Door Commanded  | --  | Varies  | This displays Counts. This is the commanded defrost door position measured in counts.  | 
Driver Heated Seat Status  | --  | Off  | The scan tool displays High, Low or Off. This is the state of the driver heated seat.  | 
Driver Temp. Dr. Motor Command  | --  | Varies  | This displays Counts. This is the commanded driver temperature door motor measured in counts.  | 
Driver Temp. Dr. Position  | --  | Varies  | This displays Counts. This is the driver temperature door position measured in counts.  | 
Ignition Voltage Signal  | --  | Varies  | This displays Volts. This is the current ignition voltage signal.  | 
Mode Door Commanded  | --  | Varies  | This displays Counts. This is the commanded mode door position measured in counts.  | 
Mode Door Position  | --  | Varies  | This displays Counts. This is the current mode door position measured in counts.  | 
Mode Status  | --  | Varies  | The scan tool displays Invalid, Vent, Mix-Blend, Floor, Bi-Level, Defrost or Recirc. This is the mode status.  | 
Passenger Heated Seat Status  | --  | Off  | The scan tool displays High, Low or Off. This is the state of the passenger heated seat.  | 
Psgr. Temp. Dr. Motor Command  | --  | Varies  | This displays Counts. This is the commanded passenger temperature door motor measured in counts.  | 
Psgr. Temp. Dr. Position  | --  | Varies  | This displays Counts. This is the current passenger temperature door position measured in counts.  | 
Rear Defrost LED  | --  | Off  | The scan tool displays On or Off. This is the state of the rear defrost indicator.  | 
Recirculation Dr. Motor Command  | --  | Varies  | This displays Counts. This is the commanded recirculation door motor measured in counts.  | 
Recirculation Dr. Position  | --  | Varies  | This displays Counts. This is the recirculation door position measured in counts.  | 
Output Control  | Description  | 
|---|---|
A/C Request  | The HVAC control module sends out a A/C request signal to turn on the A/C compressor when you select ON. The request signal should stay active until commanded OFF.  | 
All Status LEDs  | The scan tool displays Commanded State: On or Off. This function commands all LEDs On or Off.  | 
Auxiliary Air Temp. Door  | The HVAC control module commands the auxiliary air temperature actuator towards 255 counts when you select ON. The HVAC control module commands the auxiliary air temperature actuator towards 0 counts when commanded OFF.  | 
Auxiliary Blower Motor  | This functions commands Auxiliary Blower Motor On or Off.  | 
Auxiliary Mode Door  | The HVAC control module commands the auxiliary Mode actuator towards 255 counts when you select ON. The HVAC control module commands the auxiliary Mode actuator towards 0 counts when commanded OFF.  | 
Defrost Mode  | The HVAC control module commands the Defrost actuator towards 255 counts when you select ON. The HVAC control module commands the Defrost actuator towards 0 counts when commanded OFF.  | 
Left Temp. Door Position  | The HVAC control module commands the left air temperature actuator towards 255 counts when you select ON. The HVAC control module commands the left air temperature actuator towards 0 counts when commanded OFF.  | 
Mode Door Position  | The HVAC control module commands the Mode actuator towards 255 counts when you select ON. The HVAC control module commands the Mode actuator towards 0 counts when commanded OFF.  | 
Recalibrate All Motors  | The scan tool displays Commanded State: None or On. This functions commands all actuators to their fully opened and fully closed positions, and relearns these endpoints.  | 
Recirculation Door  | The HVAC control module commands the recirculation actuator towards 0 counts when you select ON. The HVAC control module commands the recirculation actuator towards 255 counts when you select OFF.  | 
Right Temp. Door Position  | The HVAC control module commands the right air temperature actuator towards 255 counts when you select ON. The HVAC control module commands the right air temperature actuator towards 0 counts when commanded OFF.  |