Removal Procedure
- Remove the upper instrument panel (I/P) trim pad. Refer to 
Upper Trim Pad, Outer Trim Cover, Fuse Block Access Cover Replacement - Instrument Panel
 in Instrument Panel, Gages, and Console.
 
- Locate the recirculation actuator (2).
 
- Disconnect the recirculation actuator electrical connector (1).
 
- Remove the recirculation actuator bolts/screws (1).
 
- Remove the recirculation actuator (7).
 
- Remove the recirculation actuator levers (3, 6), if necessary. Note positioning for re-installation.
 
Installation Procedure
- Install the recirculation actuator levers (3, 6), if necessary.
 
- Install the recirculation actuator (7).
 
Notice: Refer to Fastener Notice in the Preface section.
- Install the recirculation actuator bolts/screws (1).
 
Tighten
Tighten the screws to 1.2 N·m (11 lb in).
- Connect the recirculation actuator electrical connector (1).
 
- Install the upper I/P trim pad. Refer to 
Upper Trim Pad, Outer Trim Cover, Fuse Block Access Cover Replacement - Instrument Panel
 in Instrument Panel, Gages, and Console.
 
- Re-calibrate the actuators. Refer to 
Actuator Recalibration
 .