Removal Procedure
- Disassemble the A/C refrigerant
 components. Refer to the appropriate repair procedure
 
| •  | For compression style fittings use a back up wrench on the fitting
 (2) and loosen the fitting nut (1). | 
 
| •  | For banjo style fittings remove the bolt retaining the banjo type
 fitting. | 
 
- Remove the O-ring seal from the A/C refrigerant component.
 
- Inspect the O-ring seal for signs of damage.
 
- Inspect the A/C refrigerant components for damage or burrs. Repair
 if necessary.
 
- Discard the O-ring seal.
 
Installation Procedure
- Inspect the new O-ring seal for any sign or cracks, cuts, or damage.
 Replace if necessary.
 
- Using a lint-free clean, dry cloth, carefully clean
the sealing surfaces of the A/C refrigerant components.
 
Important: DO NOT allow any of the mineral base 525 viscosity refrigerant
 oil on the new O-ring seal to enter the refrigerant system.
- Lightly coat the new O-ring seal with mineral base 525 viscosity
 refrigerant oil.
 
Important: DO NOT reuse O-ring seals.
- Carefully slide the new O-ring seal onto the A/C refrigerant component.
 
- The O-ring seal must be
 fully seated.
 
- Assemble the A/C components.
 
Refer to the appropriate repair procedure.
| •  | For compression style fittings use a back up wrench on the fitting
 (2) and tighten the fitting nut (1) to specification. | 
 
| •  | For banjo style fittings install the bolt retaining the banjo
 type fitting and tighten to specification. |