Removal Procedure
Caution: Refer to SIR Inflator Module Handling and Storage Caution in the Preface section.
- Disable the SIR system. Refer to 
SIR Disabling and Enabling 
 .
 
- Remove the instrument panel (I/P) compartment and the electrical   connector
 from the I/P compartment lamp. Refer to 
Instrument Panel Compartment Replacement 
 in Instrument  Panel, Gages and Console.
 
- Remove the I/P module pigtail harness clips from the I/P carrier   bracket.
 
- Remove the mounting fasteners (4)
  that  attach the inflatable restraint module to the I/P.
 
- Remove the bolts (5) that attach the inflatable restraint   I/P
 module to the cross-car beam.
 
- Remove the inflatable restraint I/P module (1) from the   vehicle.
 
- Fully deploy the module before disposal. If the module was replaced  
 under warranty, fully deploy and dispose of the module after the required   retention
 period. Refer to 
Inflator Module Handling and Scrapping 
.
 
Installation Procedure
- Install the inflatable  restraint I/P  module (1)
 to the vehicle.
 
- Install the inflatable restraint I/P module bolts (5).
 
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the inflatable restraint I/P module mounting fasteners (4).
 
Tighten
Tighten fasteners to 10 N·m (89 lb in).
- Install the pigtail harness clips on the module to the I/P carrier   bracket.
 
- Install the electrical connector to the I/P compartment lamp and   install
 the I/P compartment. Refer to 
Instrument Panel Compartment Replacement 
 in Instrument  Panel, Gages  and Console.
 
- Enable the SIR system. Refer to 
SIR Disabling and Enabling 
.