2 
 | Evaporative Emission Canister  
 Procedure
- Disconnect the fuel sender wiring harness electrical connector from the EVAP canister vent solenoid valve.
 
- Disconnect the EVAP canister vent front pipe quick connect fitting from the EVAP canister. Refer to 
Plastic Collar Quick Connect Fitting Service
 .
 
- Disconnect the EVAP canister vent rear pipe quick connect fitting from the EVAP canister. Refer to 
Plastic Collar Quick Connect Fitting Service
 .
 
- Disengage the EVAP canister retainer on the fuel tank.
 
 
 |