Removal Procedure
- Disconnect the engine wiring harness electrical connector (1) from the
camshaft position (CMP) actuator solenoid valve (6).
 
- Remove the CMP actuator solenoid valve bolt (3).
 
- Remove the CMP actuator solenoid valve (2) from the cylinder head.
 
Discard the O-ring seal.
- Clean debris from the hole (1).
 
Installation Procedure
- Install a new O-ring seal to the actuator solenoid valve (2).
 
- Lightly lubricate the O-ring seal with clean engine oil.
 
- Install the CMP actuator solenoid valve (2) into the cylinder head.
 
Notice: Refer to Fastener Notice in the Preface section.
- Install the camshaft position actuator solenoid valve bolt (3).
 
Tighten
Tighten the CMP actuator solenoid valve bolt to 10 N·m (89 lb in).
- Connect the engine wiring harness electrical connector (1) to the CMP actuator
solenoid valve (6).