Tools Required
J 39400-A 
 Halogen Leak Detector
Removal Procedure
- Recover the refrigerant from the system. Refer to 
Refrigerant Recovery and Recharging
 .
 
- Remove the generator. Refer to 
Generator Replacement
 .
 
- Remove the drive belt. Refer to 
Drive Belt Replacement
 for the 2.9L engine or 
Drive Belt Replacement
 for the 3.7L engine.
 
- Disconnect the compressor electrical connectors.
 
Important: Some system pressure may still exist in the A/C compressor crankcase after you evacuate the system.
- Remove the discharge hose bolt from the compressor.
 
- Remove the suction hose from the compressor.
 
- Remove the compressor hose assembly blocks from the compressor.
 
- Remove the compressor mounting bolts from the compressor (1).
 
- Remove the compressor .
 
- Drain and measure the compressor oil. Refer to 
Air Conditioning Compressor Oil Balancing
 .
 
Installation Procedure
- Adjust the proper amount of oil to the replacement compressor. Refer to 
Refrigerant System Capacities
 .
 
- Install the compressor.
 
Notice: Refer to Fastener Notice in the Preface section.
- Install the compressor mounting bolts to the compressor (1).
 
Tighten
Tighten the bolts to 50 N·m (37 lb ft).
- Install the compressor hose assembly blocks to the compressor.
 
- Install the suction hose to the compressor
 
- Install the discharge hose bolt to the compressor (1).
 
Tighten
Tighten the bolts to 33 N·m (24 lb ft).
- Connect the compressor electrical connectors.
 
- Install the drive belt. Refer to 
Drive Belt Replacement
 for the 2.9L engine or 
Drive Belt Replacement
 for the 3.7L engine.
 
- Install the generator. Refer to 
Generator Replacement
 .
 
- Evacuate and recharge the A/C system. Refer to 
Refrigerant Recovery and Recharging
 .
 
- Leak test the fittings of the components using the 
J 39400-A 
 .