Scan Tool Parameter  | System State  | Expected Value  | Definition  | 
|---|---|---|---|
Operating Conditions: Ignition ON/Engine OFF  | |||
Battery Voltage Signal  | __  | 12.3 V  | The scan tool displays 0-20 volts. The scan tool displays the voltage as received by the module.  | 
Generator L Terminal Signal Command  | __  | 0 Percent  | The scan tool displays On/Off. The scan tool displays Off until the engine is running, at which time it will display On.  | 
Regulated Voltage Control Current Sensor  | __  | Varies  | The scan tool displays Amps. This controls how much current is going to or from the negative battery cable.  | 
Running State of Charge  | __  | Varies  | The scan tool displays percent. This calculates the battery's state of charge based on current and voltage over a long period of time.  | 
Scan Tool Output Control  | Description  | 
|---|---|
GEN L-Terminal  | The engine control module (ECM) commands the generator OFF by removing the 5-volt reference signal from the L terminal of the voltage regulator when you select OFF. The generator will then stop generating an output voltage.  |