Air Conditioning (A/C) Refrigerant Pressure Sensor Replacement LH8
                    
Callout 
 | Component Name 
 | 
Preliminary ProcedureDisconnect the electrical connector from the pressure sensor. 
 | 
1 
 | A/C Refrigerant Pressure Sensor 
Caution: Refer to Fastener Caution in the Preface section. 
Tighten 5 N·m (44 lb in)  | 
2 
 | O-ring Seal 
Tip Remove and discard the O-ring. Refer to 
O-Ring Replacement.  | 
                            Air Conditioning (A/C) Refrigerant Pressure Sensor Replacement LLV, LLR
                    Tools Required
J 39400-A  Halogen Leak Detector
Removal Procedure
- Disconnect the A/C refrigerant pressure sensor electrical connector.
 
- Remove the A/C refrigerant pressure sensor from the evaporator inlet tube.
 
Installation Procedure
- Using a lint-free clean, dry cloth, carefully clean the sealing surfaces of the evaporator inlet tube fitting.
 
Note: DO NOT allow any of the mineral base 525 viscosity refrigerant oil on the O-ring seal to enter the refrigerant system.
- Lightly coat the O-ring seal with mineral base 525 viscosity refrigerant oil.
 
Caution: Refer to Fastener Caution in the Preface section.
- Install the A/C refrigerant pressure sensor to the evaporator inlet tube. Tighten the sensor to 
5 N·m (44 lb in).
 
- Connect the A/C refrigerant pressure sensor electrical connector.
 
- Leak test the fittings of the component using 
J 39400-A .