Removal Procedure
- Remove the camshaft position (CMP) sensor electrical connector (1).
 
- Remove the CMP sensor retaining bolt.
 
Installation Procedure
Caution: Refer to Fastener Caution in the Preface section.
- Install the CMP sensor and tighten the bolt to 
10 N·m (89 lb in).
 
- Install the CMP sensor electrical connector (1).