Removal Procedure
- Remove air cleaner outlet
duct. Refer to 
Air Cleaner Resonator Outlet Duct Replacement 
.
 
- Disconnect the mass air flow/intake air temperature (MAF/IAT)
sensor electrical connector (4).
 
- Loosen the air cleaner housing cover screws (8).
 
- Remove the air cleaner housing cover (4). 
 
- Remove the air filter element (5).
 
- Inspect the air filter element for dust, dirt, or water. Clean
or replace the air filter element as required.
 
Installation Procedure
- Install the air filter element (5).
 
- Install the air cleaner housing cover (4).
 
- Tighten the air cleaner housing cover screws (8) until snug.
 
- Connect the MAF/IAT (4)
sensor electrical connector.
 
- Install air cleaner outlet duct. Refer to 
Air Cleaner Resonator Outlet Duct Replacement 
.