Checks  | Causes  | 
|---|---|
TCC Circuit  | Blockage during apply or release  | 
Pump Cover (215)  | Cross channel leakage  | 
Pressure Regulator Valve (216)  | The valve is stuck in a high demand position  | 
Oil Cooler  | The cooler or the cooler lines are blocked  | 
Oil Pan Gasket (73)  | The gasket is damaged  | 
Turbine Shaft O-ring (618)  | The O-ring is damaged  | 
Turbine Shaft Seals (619)  | The seals are damaged  | 
Stator Shaft Bushings (234/241)  | The bushing is worn or damaged  | 
Fluid  | The fluid level is low  | 
Radiator  | Air flow is restricted or internal blockage  |