Step  | Action  | Value(s)  | Yes  | No  | 
|---|---|---|---|---|
1  | Has the HVAC Blower Controls System Check been performed?  | --  | Go to Step 2  | |
2  | 
 Does the auxiliary blower motor spin?  | --  | Go to Step 3  | Go to Step 4  | 
3  | Replace the auxiliary blower resistor. Refer to Auxiliary Blower Motor Resistor Replacement . Is the repair complete?  | --  | --  | |
4  | 
 Is continuity present?  | --  | Go to Step 6  | Go to Step 5  | 
5  | Locate and repair the open in CKT 1172 (YEL) between the resistor connector and splice S402. Refer to Wiring Repairs in Wiring Systems. Is the repair complete?  | --  | --  | |
6  | 
 Does the auxiliary blower motor operate in all positions tested?  | --  | Go to Step 10  | Go to Step 7  | 
7  | 
 Is continuity present on both switches?  | --  | Go to Step 9  | Go to Step 8  | 
8  | Replace the auxiliary HVAC control module. Refer to Auxiliary Air Conditioning (A/C) Control Assembly Replacement - Front or Control Assembly Replacement - Auxiliary . Is the repair complete?  | --  | ||
9  | Locate and repair the open the circuit(s) between cavity 2 of the relay socket and the auxiliary HVAC control modules, front and rear. Refer to Wiring Repairs in Wiring Systems. Is the repair complete?  | --  | --  | |
10  | Replace both auxiliary blower motor relays. Refer to Auxiliary Blower Motor Relay Replacement . Is the repair complete?  | --  | --  |