Step
| Action
| Value(s)
| Yes
| No
|
DEFINITION: A constant rush of air is typical of high-speed blower operation.
Some systems and modes are noisier than others. Check another similar vehicle,
if possible, to determine whether the noise is typical or excessive
|
1
| Did you perform the Functional Check?
| --
| Go to
Step 2
| Go to
Function Test
|
2
|
- Inspect the defroster nozzle.
- Remove any foreign objects
- Repair any loose instrument panel pad that blocks an outlet.
| --
| Go to
Step 3
| Go to
Air Outlet Duct Replacement - Right Defogger
|
3
|
- Place the ignition switch in the RUN position.
- Move the temperature control knob from extreme cold to extreme hot one
step at a time.
- Check vacuum source to defroster air valve vacuum actuator.
- Monitor the defroster air valve vacuum actuator.
Does the shaft move when moving the knob?
| --
| Go to
Step 4
| Go to
Temperature Actuator Replacement
|
4
|
- The problem is not electrical.
- Ensure that the vehicle is reaching the normal operating temperature.
Is the vehicle reaching the normal operating temperature?
| --
| Go to
Step 5
| Go to
Engine Coolant Thermostat Replacement
|
5
| Heating insufficient.
| --
| --
| Go to
Heating Insufficient
|