Air Conditioning (A/C) Refrigerant Pressure Sensor Replacement Non-HP2
                    Special Tools
J 39400-A  Halogen Leak Detector
Removal Procedure
- Disconnect the electrical connector from the A/C refrigerant pressure sensor.
 
- Remove the A/C refrigerant pressure sensor (1) from the condenser tube.
 
Installation Procedure
Caution: Refer to Fastener Caution in the Preface section.
- Install the A/C refrigerant pressure sensor (1).
 
Tighten
Tighten the switch to 6 N·m (53 lb in).
- Connect the electrical connector to the A/C refrigerant pressure sensor.
 
- Leak test the fittings of the components using the 
J 39400-A .
 
- Lower the vehicle.