Range  | Pressure Switch 1 - N/O  | Pressure Switch 2 - N/O  | Pressure Switch 3 - N/O  | Pressure Switch 4 - N/C  | ||||
|---|---|---|---|---|---|---|---|---|
Switch Status  | Scan Tool Status  | Switch Status  | Scan Tool Status  | Switch Status  | Scan Tool Status  | Switch Status  | Scan Tool Status  | |
R  | Open  | HIGH*  | Closed  | LOW  | Closed  | LOW  | Closed  | LOW  | 
N  | Closed  | LOW  | Closed  | LOW  | Closed  | LOW  | Open  | HIGH  | 
1  | Open  | HIGH  | Closed  | LOW  | Open  | HIGH  | Open  | HIGH  | 
2  | Open  | HIGH  | Open  | HIGH  | Open  | HIGH  | Open  | HIGH  | 
3  | Closed  | LOW  | Open  | HIGH  | Open  | HIGH  | Open  | HIGH  | 
4  | Closed  | LOW  | Open  | HIGH  | Closed  | LOW  | Open  | HIGH  | 
5  | Open  | HIGH  | Open  | HIGH  | Closed  | LOW  | Open  | HIGH  | 
6  | Open  | HIGH  | Open  | HIGH  | Closed  | LOW  | Open  | HIGH  | 
N/C = Normally Closed N/O = Normally Open * Pressure switch 1 (PS1) reverts to the Closed/LOW state with throttle applied in REVERSE.  | ||||||||