| • | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. | 
| • | Review Strategy Based Diagnosis for an overview of the diagnostic approach. | 
| • | Diagnostic Procedure Instructions provides an overview of each diagnostic category. | 
Circuit  | Short to Ground  | Open/High Resistance  | Short to Voltage  | Signal Performance  | 
|---|---|---|---|---|
ECT Sensor Signal  | P0117  | P0118  | P0118  | P0116, P0128  | 
Low Reference  | --  | P0118  | P0118  | P0128  | 
Circuit  | Short to Ground  | Open  | Short to Voltage  | 
|---|---|---|---|
Operating Conditions: Engine Running Parameter Normal Range: -39 to +120°C (-38 to +248°F)  | |||
ECT Sensor Signal  | 149°C (300°F)  | -40°C (-40°F)  | -40°C (-40°F)  | 
Low Reference  | --  | -40°C (-40°F)  | -40°C (-40°F)  | 
The engine coolant temperature (ECT) sensor is a variable resistor that measures the temperature of the engine coolant. The engine control module (ECM) supplies 5 volts to the ECT signal circuit, and a ground for the ECT low reference circuit.
| • | The ignition is ON. | 
| • | DTC P0117 runs continuously within the enabling condition. | 
| • | The ignition is ON. | 
| • | DTC P0118 runs continuously within the enabling condition. | 
The ECM detects that the ECT Sensor is warmer than 149°C (300°F) for more than 10 seconds.
The ECT sensor temperature is colder than -39°C (-38°F) for more than 60 seconds.
DTCs P0117 and P0118 are Type A DTCs.
DTCs P0117 and P0118 are Type A DTCs.
An ECT sensor signal circuit or low reference circuit that is shorted to another 5-volt reference circuit can cause a DTC P0118 to set.
Powertrain Diagnostic Trouble Code (DTC) Type Definitions
Control Module References for scan tool information
| ⇒ | If greater than the specified range, test the low reference circuit for an open/high resistance. If the circuit tests normal, replace the ECM. | 
| ⇒ | If greater than the specified range, test the signal circuit terminal B for a short to ground. If the circuit tests normal, replace the ECM. | 
| ⇒ | If less than the specified range, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the ECM. | 
Measure and record the resistance of the ECT sensor at various ambient temperatures and compare those measurements to the Temperature vs. Resistance Table. Refer to Temperature Versus Resistance.
| • | Control Module References for ECM replacement, setup, and programming | 
| ⇒ | If the Soot Mass value is less than 30 grams, perform the Diesel Particulate Filter (DPF) Regeneration Enable | 
| ⇒ | If the Soot Mass value is greater than 30 grams, perform the Diesel Particulate Filter (DPF) Service Regeneration |