| Table 1: | A/C Performance Table | 
This test measures the operating efficiency of the A/C system under the following conditions:
| • | The current ambient air temperature | 
| • | The current relative humidity | 
| • | The high side pressure of the A/C system | 
| • | The low side pressure of the A/C system | 
| • | The temperature of the air being discharged into the passenger compartment | 
The numbers below refer to the step numbers on the diagnostic table.
This step determines if the A/C system has at least the minimum refrigerant charge required to operate the system without damage.
This step measures the performance of the A/C system.
This step is to allow for vehicle variations as well as high ambient temperatures.
Step  | Action  | Values  | Yes  | No  | ||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 
 Important: 
  | ||||||||||||||||||||||||||||
 Are both the low side and high side pressures within the specified value?  | More than 16°C (60°F) - 345 kPa (50 psi) More than 24°C (75°F) - 483 kPa (70 psi) More than 33°C (90°F) - 690 kPa (100 psi)  | Go to Step 2  | Go to Leak Testing  | |||||||||||||||||||||||||
 Important: Record the relative humidity and the ambient air temperature at the time of the test. 
 
 
 
 
 
 
 
 
 
 
 
 Does all the data recorded fall within the specified ranges of the table below?  | --  | Go to Step 8  | Go to Step 3  | |||||||||||||||||||||||||
If the pressures and temperatures recorded do not fall within the specified ranges: 
 Does all the data recorded fall within the specified ranges of the table below?  | --  | Go to Step 8  | Go to Step 4  | |||||||||||||||||||||||||
4  | Do the high and low side pressures fall within the specified ranges, but the outlet temperatures do not?  | --  | Go to Step 5  | |||||||||||||||||||||||||
5  | Is the low side pressure greater than the specified range, but the high side pressure within or less than the specified range?  | --  | Go to Step 6  | |||||||||||||||||||||||||
6  | Are the low and high side pressures both greater than the specified ranges?  | --  | Go to Step 7  | |||||||||||||||||||||||||
7  | Is the high side pressure greater than the specified range, but the low side pressure is within or less than the specified range?  | --  | Go to Step 8  | |||||||||||||||||||||||||
8  | Operate the system in order to verify the test results. Did you find the same results?  | --  | System OK  | |||||||||||||||||||||||||
Ambient Air Temperature  | Relative Humidity  | Service Port Pressure  | Maximum Left Center Discharge Air Temperature  | |
|---|---|---|---|---|
Low Side  | High Side  | |||
13-18°C (55-65°F)  | 0-100%  | 259-358 kPa (38-52 psi)  | 1210-1590 kPa (176-231 psi)  | 4°C (39°F)  | 
19-24°C (66-75°F)  | Below 40%  | 280-391 kPa (41-57 psi)  | 1380-1780 kPa (200-258 psi)  | 5°C (42°F)  | 
Above 40%  | 301-410 kPa (44-61 psi)  | 1440-1870 kPa (209-271 psi)  | 8°C (46°F)  | |
25-29°C (77-84°F)  | Below 35%  | 334-430 kPa (49-62 psi)  | 1650-1990 kPa (239-288 psi)  | 9°C (48°F)  | 
35-60%  | 348-440 kPa (51-64 psi)  | 1690-2030 kPa (245-295 psi)  | 9°C (48°F)  | |
Above 60%  | 358-462 kPa (52-67 psi)  | 1720-2100 kPa (250-305 psi)  | 10°C (50°F)  | |
30-35°C (86-95°F)  | Below 30%  | 375-476 kPa (54-69 psi)  | 1860-2240 kPa (270-325 psi)  | 11°C (52°F)  | 
30-50%  | 386-491 kPa (56-71 psi)  | 1900-2300 kPa (276-334 psi)  | 15°C (60°F)  | |
Above 50%  | 400-513 kPa (58-75 psi)  | 1950-2390 kPa (283-347 psi)  | 16°C (61°F)  | |
36-41°C (97-106°F)  | Below 20%  | 422-519 kPa (61-75 psi)  | 2100-2470 kPa (304-359 psi)  | 16°C (61°F)  | 
20-40%  | 429-534 kPa (62-78 psi)  | 2130-2540 kPa (309-369 psi)  | 18°C (64°F)  | |
Above 40%  | 444-549 kPa (64-80 psi)  | 2190-2600 kPa (317-377 psi)  | 18°C (64°F)  | |
42-46°C (108-115°F)  | Below 20%  | 472-561 kPa (69-81 psi)  | 2360-2680 kPa (343-389 psi)  | 20°C (68°F)  | 
Above 20%  | 479-576 kPa (70-84 psi)  | 2390-2760 kPa (347-401 psi)  | 21°C (69°F)  | |
47-49°C (117-120°F)  | Below 30%  | 521-594 kPa (76-86 psi)  | 2600-2850 kPa (377-414 psi)  | 22°C (72°F)  |