Step  | Action  | Yes  | No  | ||||||
|---|---|---|---|---|---|---|---|---|---|
DEFINITION: Heating system performance.  | |||||||||
1  | Were you sent here from Symptoms or another diagnostic table?  | Go to Step 2  | |||||||
2  | 
 Does the engine reach a normal operating temperature?  | Go to Step 3  | Go to Step 15  | ||||||
3  | 
 Caution: Refer to Moving Parts and Hot Surfaces Caution in the Preface section. Does the inlet heater hose feel warmer than the outlet heater hose?  | Go to Step 11  | Go to Step 4  | ||||||
4  | Disconnect the vacuum hose from the hot water bypass valve. Is vacuum being applied to the valve?  | Go to Step 14  | Go to Step 5  | ||||||
5  | Remove the hot water bypass valve. Refer to Heater Water Shutoff Valve Replacement . Inspect the hot water bypass valve for the following conditions: 
 
 
 Are any of the listed conditions present?  | Go to Step 13  | Go to Step 6  | ||||||
6  | Install the hot water bypass valve. Refer to Heater Water Shutoff Valve Replacement . Is the action complete?  | Go to Step 7  | --  | ||||||
7  | 
 Does the inlet heater hose feel warmer than the outlet heater hose?  | Go to Step 11  | Go to Step 8  | ||||||
8  | 
 
 
 Are the two temperature readings about equal?  | Go to Step 9  | Go to Step 10  | ||||||
9  | 
 
 
 
 Are the repairs complete?  | Go to Step 16  | --  | ||||||
10  | 
 Is the repair complete?  | Go to Step 16  | --  | ||||||
11  | 
 Does the inlet heater hose feel warmer than the outlet heater hose?  | Go to Step 12  | Go to Step 16  | ||||||
12  | Replace the heater core. Refer to Heater Core Replacement . Is the repair complete?  | Go to Step 16  | --  | ||||||
13  | Replace the hot water bypass valve. Refer to Heater Water Shutoff Valve Replacement . Is the repair complete?  | Go to Step 16  | --  | ||||||
14  | Repair the vacuum condition. Refer to Vacuum Control System Diagnostic . Is the repair complete?  | Go to Step 16  | --  | ||||||
15  | Repair the low engine temperature concern. Refer to Symptoms - Engine Cooling . Is the repair complete?  | Go to Step 16  | |||||||
16  | Operate the system in order to verify the repair. Did you find and correct the condition?  | System OK  | Go to Step 2  | ||||||