Special Tools
J 39400-A 
 Halogen Leak Detector
Removal Procedure
- Recover the refrigerant from the air conditioning (A/C) system. Refer to 
Refrigerant Recovery and Recharging
 .
 
- Remove the right wheelhouse panel. Refer to 
Wheelhouse Panel Replacement
 .
 
- Remove the air cleaner. Refer to the appropriate procedure:
 
- Disconnect the low pressure sensor electrical connector.
 
- Disconnect the blower motor assembly electrical connector.
 
- Disconnect the blower motor resistor assembly electrical connector.
 
- Remove the multi-use module bracket. Refer to the appropriate procedure:
 
| •  | Caterpillar® 3126 Unit Repair Manual | 
 
- Remove the evaporator outlet hose retaining nut (5) from the accumulator.
 
- Remove the compressor inlet hose retaining nut (2).
 
- Disconnect the low pressure sensor electrical connector.
 
- Remove the retaining nuts (3) from the accumulator retaining bracket.
 
- Remove the accumulator (5) from the bracket. 
 
- Remove the O-ring seals.
 
- Remove the retaining nut (3) from the evaporator inlet tube (5).
 
- Remove the evaporator inlet tube from the evaporator.
 
- Remove the O-ring seal.
 
- Remove the retaining nut (4) from the evaporator outlet tube (3).
 
- Remove the evaporator outlet tube from the evaporator.
 
- Remove the O-ring seal.
 
- Remove the evaporator and blower module assembly (3).
 
Installation Procedure
- Install the evaporator and blower module assembly (3).
 
Notice: Refer to Fastener Notice in the Preface section.
- Install the evaporator and blower module assembly retaining nuts (2).
 
Tighten
Tighten the nuts to 6 N·m (53 lb in).
- Install new O-ring seals to the evaporator inlet and outlet tubes. Refer to 
O-Ring Replacement
 .
 
- Install the evaporator inlet tube (4) to the evaporator.
 
- Install the evaporator inlet tube retaining nut.
 
Tighten
Tighten the nut to 18 N·m (13 lb ft).
- Install the evaporator outlet tube (3) to the evaporator.
 
- Install the evaporator outlet tube retaining nut.
 
Tighten
Tighten the nut to 18 N·m (13 lb ft).
- Install the accumulator (5) to the bracket. 
 
- Install the nuts (3) to the accumulator retaining bracket.
 
Tighten
Tighten the nuts to 9 N·m (80 lb in).
- Connect the low pressure sensor electrical connector.
 
- Install new O-ring seals. Refer to 
O-Ring Replacement
 .
 
- Install the evaporator outlet hose.
 
- Install the evaporator outlet hose retaining nut (5) to the accumulator.
 
Tighten
Tighten the nut to 18 N·m (13 lb ft).
- Install the compressor inlet hose.
 
- Install the compressor inlet hose retaining nut (2) to the accumulator.
 
Tighten
Tighten the nut to 18 N·m (13 lb ft).
- Install the multi-use module bracket. Refer to the appropriate procedure:
 
| •  | Caterpillar® 3126 Unit Repair Manual | 
 
- Connect the low pressure sensor electrical connector.
 
- Connect the blower motor assembly electrical connector.
 
- Connect the blower motor resistor assembly electrical connector.
 
- Install the air cleaner. Refer to the appropriate procedure:
 
- Install the right wheelhouse panel. Refer to 
Wheelhouse Panel Replacement
 .
 
- Evacuate and recharge the A/C system. Refer to 
Refrigerant Recovery and Recharging
 .
 
- Leak test the fittings of the components using the 
J 39400-A 
 .