Step  | Action  | Value(s)  | Yes  | No  | ||||
|---|---|---|---|---|---|---|---|---|
Schematic Reference: Instrument Cluster Schematics  | ||||||||
1  | Did you perform the Instrument Cluster Diagnostic System Check?  | --  | Go to Step 2  | |||||
2  | 
 Does the Displayed Trans Oil Temp parameter match the transmission fluid temperature gage display?  | --  | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems  | Go to Step 3  | ||||
3  | 
 Does the scan tool indicate both parameters are approximately the same?  | --  | Go to Step 4  | Go to Step 5  | ||||
4  | With the scan tool observe the Monitored Trans Oil Temp parameter in the IPC data list. Does the scan tool indicate the parameter is within the specified range?  | 38°C to 130°C (100°F to 265°F)  | Go to Step 5  | Go to 
 
  | ||||
5  | Replace the IPC. Refer to Instrument Cluster Replacement . Did you complete the replacement?  | --  | Go to Step 6  | --  | ||||
6  | Operate the system in order to verify the repair. Did you correct the condition?  | --  | System OK  | Go to Step 2  | ||||