Important: The rear defogger bus bar lead wire, the antenna, or the defogger terminal
may be reattached by resoldering using a solder containing 3 percent
      silver and a rosin flux paste.
- Clean the repair area by buffing with fine steel wool. This removes
the oxide coating formed during the window manufacture.
 
- Install the paste-type rosin flux in small quantities to
the rear defogger bus bar lead wire antenna or the defogger terminal repair
      area using a brush.
 
- Coat the solder iron tip with the solder.
 
| •  | Use only enough heat in order to melt the solder. | 
 
| •  | Use only enough solder in order to ensure a complete repair. | 
 
- Install the solder to the feed bus bar or the ground bus bar.
 
- Draw the soldering iron tip across the fluxed area, thinly coating
the bus bar with solder.
 
- Install a small amount of flux to the underside of the rear defogger
bus bar lead wire antenna or the defogger terminal.
 
- Align the spots with flux to the underside of the rear defogger
bus bar lead wire, antenna, or defogger terminal.
 
- Coat the tip of the soldering iron with solder.
 
- Install the solder to the underside of the rear defogger bus bar
lead wire antenna to the defogger terminal.
 
- Draw the iron across the fluxed spot, thinly coating the spot
of solder.
 
- Solder the spot on the braid against the spot on the feed bus
bar or the ground bus bar.
 
| •  | Use pliers in order to hold the rear defogger bus bar lead wire
antenna or the defogger terminal. | 
 
| •  | Apply the heat to the top of the rear defogger bus bar lead wire
antenna or the defogger terminal. This causes the solder spot to melt and
        fuse together. | 
 
| •  | Do not remove the holding force until the solder has solidified. | 
 
| •  | Wipe off the excess flux with solvent. | 
 
- Connect the electrical connector.