A/C High Side Pressure : The scan tool displays  0-3450 kPa (0-500 psi). The  voltage applied to the PCM input from the A/C refrigerant pressure sensor   is converted to a pressure value.
A/C High Side Pressure : The scan tool displays 0-5 volts. The voltage applied to  the PCM input for the A/C refrigerant pressure sensor.
A/C Switch: The scan tool displays On/Off. The scan tool displays On when the  A/C request switch is active. The scan tool displays Off when the A/C request   switch is inactive.
AC/Heater Door Actual: The scan tool displays 0-255 Counts. The voltage applied  to the HVAC control module input for the mode door position is converted to   a number between 0 and 255 where 51 Counts is approximately equal  to  1 V. 
AC/Heater Door Commanded: The scan tool displays 0-255 counts. The scan tool displays  the desired mode door position as determined by the HVAC control module.
AC/Heater Motor Drive: The scan tool displays Stop, Increase, or Decrease. The scan tool  displays the control decision for the actuator output as determined by the   HVAC control module.
A/C Relay Command: The scan tool displays On/Off. The scan tool displays the control  decision for the compressor clutch relay output as determined by the PCM.
A/C Request Signal: The scan tool displays Yes/No. The scan tool displays Yes when  the PCM receives a class 2 message from the HVAC control module to   engage the A/C compressor clutch. The scan tool displays No when the PCM  receives  a class 2 message from the HVAC control module to disengage  the A/C  compressor clutch.
Air Inlet Drive Motor: The scan tool displays Fresh Air or Recirc. The scan tool  displays Recirc. when the recirculation actuator is closed.
Air Mix Door Left Commanded: The scan tool displays 0-255 counts. The scan tool displays  the desired left air temperature door position as determined by the HVAC control   module.
Air Mix Door Right Commanded: The scan tool displays 0-255 counts. The scan tool displays  the desired right air temperature door position as determined by the HVAC  control  module.
Battery Voltage: The scan tool displays 0-25 volts. The voltage measured from  the battery positive voltage circuit and the ground circuit of the HVAC control   module.
ECT Sensor: The scan tool displays -39 to 140°C (-38 to 284°F) . The  voltage applied to the PCM input from the engine coolant temperature sensor   is converted to a temperature value.
ECT Sensor: The scan tool displays 0-5 volts. The voltage applied to  the PCM input for the engine coolant temperature sensor.
Ign. Since Current DTC: The scan tool displays 0-100. The number of the ignition  cycles since the setting of the most recent current diagnostic trouble code   (DTC).
Left Mix Door Actual: The scan tool displays 0-255 counts. The voltage applied  to the left air temperature door position input of the HVAC control module   is converted to a number between 0 and 255 where 51 Counts is approximately   equal to 1 V.
Left Mix Motor Drive: The scan tool displays Stop, Increase, or Decrease. The scan tool  displays the control decision for the actuator output as determined by the   HVAC control module.
Left Solar Sensor: The scan tool displays 0-255 counts. The voltage applied  to the left sunload input of the BCM is converted to a number between 0 and   255 where 51 Counts is approximately equal to 1 V.
Left Temp. Detent Pos.: The scan tool displays 0 to 18. The scan  tool displays the position of the left air temperature switch.
Mode Door Actual: The scan tool displays 0-255 counts. The voltage applied  to the auxiliary mode door position input of the auxiliary HVAC control module is converted   to a number between 0 and 255 where 51 Counts is approximately equal   to 1 V.
Mode Select Position: The scan tool displays Off, Defrost, Heater, Htr/Def, Bi-Level,  Panel. The scan tool displays the state of mode operation.
Pressure Cycle Switch: The scan tool displays Low Pressure/Normal. The current state of  the input from the A/C low pressure switch. The scan tool displays Low Pressure   when the switch is open and displays Normal when the switch is closed. The   low pressure switch opens when low side pressure decreases to approximately   151 kPa (22 psi) and closes when the low side pressure increases to   approximately 275 kPa (40 psi).
Rear Blower Speed: The scan tool displays Off, Low, Med or High. The commanded state of the auxiliary blower motor as determined by the auxiliary HVAC control module.
Rear HVAC: The scan tool displays Disabled/Enabled. The scan tool displays  Disabled when the HVAC control module is in the front defrost mode. The HVAC   control module transmits a class 2 message to the auxiliary HVAC control   module in order to disable auxiliary operation while in the defrost mode.   The scan tool displays Enabled in all other modes of operation.
Rear HVAC Fan Down Switch: The scan tool displays Active or Inactive. The scan tool displays Active when the  fan down switch is pressed. The scan tool displays Inactive when the fan down switch   is not used.
Rear HVAC Fan Speed: The scan tool displays Off, Low, Med or High. The commanded state of the auxiliary blower motor as determined by the auxiliary HVAC control module.
Recirculate Switch: The scan tool displays On/Off. The scan tool displays On when the  recirculation switch is active. The scan tool displays Off when the recirculation   switch is inactive.
Right Mix Door Actual: The scan tool displays 0-255 counts. The voltage applied  to the right air temperature door position input of the HVAC control  module  is converted to a number between 0 and 255 where 51 Counts  is approximately  equal to 1 V.
Right Motor Drive: The scan tool displays Stop, Increase, or Decrease. The scan tool  displays the control decision for the actuator output as determined by the   HVAC control module.
Right Temp. Detent Pos.: The scan tool displays 0 to 18. The scan  tool displays the position of the right air temperature switch.