Removal Procedure
- Remove the vacuum hose from the pump.
 
- Disconnect the electrical connector.
 
- Remove the pump nuts.
 
- Remove the pump from the booster by pulling the inlet tube out of the grommet.
 
Installation Procedure
- Install the pump to the booster by pushing the inlet tube into the grommet and aligning the studs to the holes.
 
Notice: Refer to Fastener Notice in the Preface section.
- Install the pump nuts.
 
Tighten
Tighten the nuts to 18N·m (13 lb ft).
- Connect the electrical connector.
 
- Install the vacuum hose to the pump.