Important: Do not remove the positive crankcase ventilation (PCV) valve
grommet from the cover unless service is required.
If the grommet has been removed from the cover, a NEW grommet must be
installed.
- Remove the ignition coil and bracket assembly and bolts.
- Remove the valve rocker
arm cover bolts.
- Remove the valve rocker arm cover.
- Remove the gasket (1) from the cover.
- Discard the gasket.
The bolt grommets may be used
again if not damaged.
- Remove the ignition coils,
wire harness, and bolts from the bracket, if required.