Step  | Action  | Yes  | No  | ||||||
|---|---|---|---|---|---|---|---|---|---|
DEFINITION: Noise originating from the blower motor.  | |||||||||
1  | Were you sent here from Symptoms or another diagnostic table?  | Go to Step 2  | |||||||
2  | Inspect the air inlet grille for debris. Is debris present?  | Go to Step 8  | Go to Step 3  | ||||||
3  | 
 Is a noise evident during the blower operation?  | Go to Step 4  | Go to Step 12  | ||||||
4  | Inspect for excessive vibration at each blower motor speed by feeling the blower case. Is excess vibration present?  | Go to Step 6  | Go to Step 5  | ||||||
5  | Listen to the blower motor at each speed. Is the blower motor making a squeaking or chirping noise?  | Go to Step 9  | Go to Step 12  | ||||||
6  | 
 Did you find any foreign material on the blower motor or blower motor impeller?  | Go to Step 8  | Go to Step 7  | ||||||
7  | Inspect the blower motor for the following conditions: 
 
 
 Did you find any of these conditions?  | Go to Step 11  | Go to Step 10  | ||||||
8  | Remove the foreign material. Is the action complete?  | Go to Step 10  | --  | ||||||
9  | Replace the blower motor. Refer to Blower Motor Replacement . Is the repair complete?  | Go to Step 12  | --  | ||||||
10  | Install the blower motor. Refer to Blower Motor Replacement . Is the action complete?  | Go to Step 12  | --  | ||||||
11  | Replace the blower motor. Refer to Blower Motor Replacement . Is the action complete?  | Go to Step 12  | --  | ||||||
12  | Operate the system in order to verify the repair. Did you find and correct the condition?  | System OK  | Go to Step 2  | ||||||