Step  | Action  | Yes  | No  | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DEFINITION: Noise originating from the HVAC module.  | |||||||||||||||
1  | Were you sent here from Symptoms or another diagnostic table?  | Go to Step 2  | |||||||||||||
2  | 
 
 
 
 
 
 
 Is a scrape or pop noise evident when selecting modes or temperature settings?  | Go to Step 6  | Go to Step 3  | ||||||||||||
3  | Is a tick/click, chirping, groaning, or scraping noise present, but decreases as blower motor speed is decreased?  | Go to Step 6  | Go to Step 4  | ||||||||||||
4  | Is an air rush/whistle noise evident in all modes, but not all temperature settings?  | Go to Step 6  | Go to Step 5  | ||||||||||||
5  | Is an air rush/whistle noise evident only in defrost or floor mode?  | Go to Step 6  | Go to Step 6  | ||||||||||||
6  | Remove the instrument panel to the service position. Refer to Instrument Panel Service Positioning. Is the action complete?  | Go to Step 7  | --  | ||||||||||||
7  | 
 
 Were any of these conditions found?  | Go to Step 10  | Go to Step 8  | ||||||||||||
8  | Inspect the mode and temperature doors and seals for warping or cracking. Are the doors in normal condition?  | Go to Step 11  | Go to Step 9  | ||||||||||||
9  | Replace the appropriate door and/or seals. Is the repair complete?  | Go to Step 11  | --  | ||||||||||||
10  | Remove any obstructions or foreign material found. Is the action complete?  | Go to Step 11  | --  | ||||||||||||
11  | Install the instrument panel. Refer to Instrument Panel Service Positioning. Is the action complete?  | Go to Step 12  | --  | ||||||||||||
12  | Operate the system to verify the repair. Did you find and correct the condition?  | System OK  | Go to Step 2  | ||||||||||||