Caution: Refer to Fuel and Evaporative Emission Pipe Caution in the Preface section.
Caution: Refer to Gasoline/Gasoline Vapors Caution in the Preface section.
Notice: Refer to Fuel and Evaporative Emission Hose/Pipe Connection Cleaning Notice in the Preface section.
| 8.1. | Disconnect the EVAP canister vent solenoid valve quick connect from the EVAP canister . Refer to Plastic Collar Quick Connect Fitting Service . | 
| 8.2. | Disengage the bracket retaining tab and remove the EVAP canister vent solenoid valve. | 
| 1.1. | Engage the bracket retaining tab and install the EVAP canister vent solenoid valve. | 
| 1.2. | Connect the EVAP canister vent solenoid valve quick connect to the EVAP canister . Refer to Plastic Collar Quick Connect Fitting Service . | 
Notice: Refer to Fastener Notice in the Preface section.
Tighten
Tighten the bolt to 25 N·m (18 lb ft).