| • | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
| • | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
| • | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
|---|---|---|---|---|
RVC PWR B+ | -- | -- | -- | -- |
RVC VSENSE B+ | B1390 | B1390 | -- | -- |
Ground | -- | B1390 | -- | -- |
Circuit | Short to Ground | Open | Short to Voltage |
|---|---|---|---|
Operating Conditions: Ignition ON Parameter Normal Value: 12.60 V | |||
RVC PWR B+ | 12.60 V | 12.60 V | 12.60 V |
RVC VSENSE B+ | 0.00 V | 0.00 V | 12.60 V |
The generator battery control module (GBCM) monitors the battery voltage for precision electrical power management. The GBCM monitors both the RVC PWR B+ circuit and the RVC VSENSE B+ circuit to precisely determine system voltage. If the RVC VSENSE B+ circuit is 1.5 V less than the RVC PWR B+ circuit for 7 seconds, then DTC B1390 will set.
This diagnostic runs every 100 ms.
The RVC VSENSE B+ circuit is 1.5 V less than the RVC PWR B+ circuit for 7 seconds
| • | The GBCM will request the driver information center (DIC) to display the SERVICE CHARGSYS message. |
| • | The GBCM uses the less accurate RVC PWR B+ circuit for voltage readings. |
| • | During the current ignition cycle, the difference between the less precision battery positive voltage circuit reading and the high precision battery voltage sense circuit reading is less than 1.5 V. |
| • | The SERVICE CHARGSYS DIC message will turn off 7 seconds after the voltage on the RVC VSENSE B+ circuit returns to normal. |
| • | Inspect the RVC PWR and RVC VSENSE fuses for opens. |
| • | Inspect ground G102. Verify that it is clean and tight. |
Starting and Charging Schematics
Charging System Description and Operation
Control Module References for scan tool information
| ⇒ | If not within the specified range, refer to Charging System Test. |
| • | Terminal H |
| • | Terminal F |
| ⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. |
| • | Terminal A |
| • | Terminal C |
| ⇒ | If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
Control Module References for GBCM replacement, setup, and programming