| Table 1: | Generator Battery Control Module Scan Tool Data Parameters | 
| Table 2: | Generator Battery Control Module Scan Tool Output Controls | 
Parameter  | System State  | Expected Value  | Definition  | 
|---|---|---|---|
Operating Conditions: Ignition ON, Engine OFF, Brake Released  | |||
Battery Voltage Signal  | --  | 9-14 V  | The scan tool displays 0-20 volts. The scan tool displays the battery voltage as received by the GBCM.  | 
GEN L-Terminal Signal Command  | --  | 10-90%  | The scan tool displays 0-100 percent. The scan tool displays 0-5 percent until the engine is running, then the percentage value varies depending on electrical loads.  | 
Regulated Voltage Control Current Sensor  | --  | 10-90 A  | The scan tool displays the current measured by the RVC current sensor, in amps.  | 
Scan Tool Output Control  | Description  | 
|---|---|
GEN L-Terminal  | The GBCM commands the generator On and Off.  |