Removal Procedure
- Turn the ignition OFF.
 
Important: Do not remove the engine Control Module (ECM)
from the ECM bracket .
Do not remove the ECM redundant ground wire from
the ECM.
- Remove the remote earth post bracket to engine front cover retaining bolts.
 
- Remove the camshaft position (CMP) actuator valve
electrical connector (1) from the CMP sensor (2).
 
- Remove the CMP actuator solenoid valve to engine front
cover retaining bolt (1).
 
- Remove the CMP actuator valve (2) from the engine front cover.
 
- Inspect the CMP actuator valve seal and replace as necessary.
 
Installation Procedure
- Inspect the CMP actuator valve seal for damage. Replace the seal if necessary.
 
- Install the CMP actuator valve (2) to the engine front
cover.
 
Notice: Refer to Fastener Notice in the Preface section.
- Install the CMP actuator solenoid valve to engine front cover retaining bolt (1).
 
Tighten
Tighten the bolt to 10 N·m (89 lb in).
- Install the CMP actuator valve electrical connector
(1) to the CMP sensor (2).
 
- Install the remote earth post bracket to engine front cover retaining
bolts.